Status
RUN
commanded auto
Power draw
4.9 kW
rated 7.5 HP (5.6 kW)
Run hours
14,210
lifetime
Health
91 /100
runtime + vibration composite
Energy meter
panel kW
no dedicated meter
Power draw — 30 dkW · daily mean while running
Range
Slow upward creep in specific power usually means impeller wear or a throttled discharge valve — flagged automatically at +10% vs the 90-day floor.
Live readings1 min sampling
| Run status | RUN |
| Motor current | 7.8 A |
| Speed | 2,950 rpm (DOL) |
| Est. flow | ≈ 51 m³/h |
| Winding temp | 72 °C |
| Vibration (manual log) | NORMAL |
Health
Maintenance & nameplatefrom CMMS
| Duty group | Banquet 7.5 HP |
| Rated power | 7.5 HP (5.6 kW) |
| Starter | DOL · auto rotation with standby |
| Run hours | 14,210 |
| Greasing due | every 2,000 h · next in 1,790 h |
| Alignment check | OK (last quarter) |
| Mech. seal | No leakage reported |